Fire protection doors, thermally insulated, fire resistance rating 60 minutes - 31

Construction

  • Thermally insulated aluminium fire protection construction
  • in accordance with DIN 4102-5 and DIN EN 1634-1 (T60-1 / -2 -FSA and T60-1 / -2 -RS-FSA) for single- and double-leaf doors,
  • opening in or out in Germany with case-by-case approval
  • F60 fire-resistant glazing in accordance with DIN 4102-13 and EN 1634-1 in Germany with case-by-case approval

Sizes / dimensions

  • single-leaf: max. clearance W x H 1400 x 2534 mm
  • double-leaf: max. clearance W x H 2500 x 2534 mm
  • Element height of walls (fixed glazing) up to 3500 mm
  • Glass dimensions: up to max. 1250 x 2550 mm, upright and
  • horizontal format.
  • Panel dimensions: max. 571 x 2527 mm in upright format
  • leaf weight up to 250 kg

Profile depth

  • Fixed / leaf frame 77 mm